Measurement Range |
-50 to 70 ˚C |
Measurement Uncertainty |
0.1 C (from 0 to 70 C), 0.2 C (from -25 to 0 C), 0.4 C (from -50 to -25 C) |
Measurement Repeatability |
Less than 0.05 C |
Non-stability (Long-term Drift) |
Less than 0.02 C per year (when used in non-condensing environments where the annual average temperature is less than 30 C; continuously high temperatures or continuously humid environments increase drift rate) |
Time Constant (time for detector signal to reach 63 % following a step change) |
32 s |
Self-Heating |
Less than 0.01 C (typical, assuming pulsed excitation of 2.5 V DC); 0.08 C at 5 C (maximum, assuming continuous input excitation of 2.5 V DC) |
Operating Environment |
-50 to 70 C; 0 to 100 % relative humidity |
Resistance |
10,000 Ω at 25 C |
Input Voltage Requirement |
2.5 V DC excitation |
Output Voltage Range |
0 to 2.5 V DC (assuming input excitation of 2.5 V DC) |
Current Drain |
0.1 mA DC at 70 C (maximum, assuming continuous input excitation of 2.5 V DC) |
Dimensions |
100 mm length, 6 mm diameter |
Mass |
60 g |
Cable |
5 m of shielded, twisted-pair wire with santoprene rubber jacket (high water resistance, high UV stability, flexibility in cold conditions) |
Warranty |
4 years against defects in materials and workmanship |